Lead-free Wave Soldering-N Series
1. Selective sprayer ( optional )
2. Compatible with customer MES system
3. The spray is far distant from preheating zone.preventing fire hazard
4. Preheating heat pipe is U-typed and its material high temperature
resistant stainless steel sintered tube, with a servicelife of more than
12 years
5. modular design of preheating system and insulation measures are
good6、1/2HP high power wave motor, maximum peak height up to
16mm.(optional for above 20MM)
6. 1KG/10HLow amount of machine tin dross
N Comparison table of technical parameters of EIP wave soldering series
Dimension (LxWxH) |
4550x1605x1715mm |
4550x1886x1715mm |
4550x1865x1715mm |
PCB transport direction |
L--->R (R --->L Optional) |
||
Main voltage |
3P5W380VAC, 50/60HZ 110A |
3P5W380VAC, 50/60HZ 110A |
3P5W380VAC, 50/60HZ 115A |
Power supply requirements |
50KW |
||
Air power requirements |
0.3- 0.7MPa |
||
Total power |
40KW |
40KW |
40KW |
Normal power consumption |
10KW |
10KW |
10KW |
Control method |
PC+PLC |
||
Preheating method |
Hot air / infrared / spotlight optional |
||
Preheating fan speed control mode |
Promise frequency control |
||
Number of preheating zones |
3 |
||
Pre-heat zone length |
1740mm |
||
Pre-heat temperature |
Room temperature - 280°C |
||
Pre-heat temperature control |
PID+SSR mode |
||
wave running mode |
Mechanical pump |
||
Tin furnace heat pipe power |
1.0KW*12 |
||
Tin furnace capacity itin specific gravity 7.5 |
650KG |
750KG |
800KG |
Tin furnace limit withstand temperature |
MAX: 300°C |
||
Tin furnace limit the use of temperature |
MAX: 280'C |
||
Tin furnace control mode |
PID+SSRmode |
||
Peak drive power |
1/2HPx23P 220VAC |
1/2HP+1HP 3P 220VAC |
1/2HPx1 1HPx1 3P 220VAC |
Crest height adjustmant method |
Frequency conversion regulation |
||
Tin furnace heating time |
150MIN Set temperature |
180MIN Set temperature |
|
PCB transfer speed |
0- 1800mm / min |
||
PCB board width range |
80-350mm |
80-510mm |
80-610mm |
PCB board height |
Top: 110mm Bottom: 25mm |
||
PCB inlet transport height |
750±20mm |
||
Transport guide inclination |
40 70 Range adjustment |
4°-7° |
|
Transport motor power |
90W 3P 220VAC |
||
Transport motor speed control mode |
Frequency control |
||
Nitrogen consumption |
15m / h100ppm |
||
Nitrogen gas source pressure |
0.5-0.8MPA |
||
Nitrogen gas source oxygen content |
10PPM |
||
Number of nitrogen flow meters |
3 |
||
Flux flow |
10-100ml/MIN |
||
Spray pressure |
0.25MP A-0.5MPA |
||
Exhaust fan |
380VAC 750W |
||
Suction pipe diameter |
Cll200mm |